Steel backyard shed on a Penrith residential block in afternoon light

Sheds in Penrith: How Big Can You Build Without a DA?

November 13, 2026

Sheds in Penrith fall into three size brackets on an ordinary residential block. Up to 20m2, a garden shed can be exempt development, which means no approval at all as long as it meets the standards. Bigger than that, you do not need a development application (DA), but you do need a complying development certificate (CDC) from a certifier, and the shed size limit runs from 36m2 to 100m2 depending on your lot. Past those limits, it is a DA to Penrith City Council. These figures are correct at the time of writing, so have your own lot checked before you commit to a size.

How big can sheds in Penrith be without a DA?

There are two ways to build without a DA, and people mix them up. Exempt development needs no approval from anyone. Complying development skips the DA, but you still need a certificate in hand before you build.

PathwayApproval you needShed size on a residential block
Exempt developmentNoneUp to 20m2
Complying development (CDC)A certificate from a registered certifier36m2 to 100m2, set by your lot area
Development application (DA)Consent from Penrith City CouncilAnything larger, judged on merit

The 20m2 exempt limit is for garden sheds on residential land under the Codes SEPP. Size is not the only test. Height, distance from boundaries and other standards apply too, and a shed that misses any one of them is no longer exempt. The exempt route is for a garden shed. A garage for vehicles, a workshop or a shed used for a business may not count as one, so confirm with a certifier before you rely on it. On rural land, farm buildings can be exempt under a separate part of the Codes SEPP, so ask us or a certifier about your block. Most steel sheds and garages Upspec builds are bigger than 20m2, so they go through a certifier.

Shed size limit with a CDC, by lot area

For sheds and garages in Penrith on land zoned R1, R2, R3, R4 or RU5, the Housing Code pathway applies. Clause 3.20 of the Codes SEPP caps the combined gross floor area of detached sheds, garages, carports and decks, patios, pergolas and verandahs. The bands are below. A shed under the cap that meets the setbacks and the other complying development standards, such as height, can usually go down the certifier route.

Actual lot areaMaximum combined floor area with a CDC
200m2 to 300m236m2
Over 300m2 up to 600m245m2
Over 600m2 up to 900m260m2
Over 900m2100m2

The word "combined" matters. If you already have a 20m2 carport on a 600m2 lot, a new shed has 25m2 of headroom, not 45m2. A 9m x 6m shed is 54m2, so it fits under the 60m2 cap but is over the 45m2 cap.

Larger rural blocks work differently. In zones RU1, RU2, RU3, RU4, RU6 and R5, outbuildings sit under the Rural Housing Code. Clause 3A.12 sets no floor area cap in the RU zones, and only caps R5 lots under 4,000m2. Our rural sheds page covers the larger builds.

Why your actual lot area matters more than the zone

The band is set by the real area of your lot, not by the minimum lot size shown on the council's planning map. The minimum lot size is a control on subdividing. Your block is whatever the deposited plan says it is.

The two numbers are often far apart. A block with a 550m2 minimum lot size control might actually measure about 627m2. Read the control and the cap is 45m2. Read the lot and it is 60m2, so a 54m2 shed that looked impossible is allowed. Design to the lower figure and you may be cutting your shed smaller than the rules require.

The surveyed area on your deposited plan is the figure a certifier will use. If your lot sits within a few square metres of 600m2 or 900m2, get the plan confirmed before you settle on a size.

What setbacks apply to a shed in Penrith?

Under Penrith's development control plan, a shed is judged on setbacks and the building envelope, not a floor area cap. Penrith Development Control Plan 2014, Part D2, section 2.1.2 B1, sets these minimums for residential development:

  • Front: the greater of 5.5m, or the average of the neighbours' setbacks. Garages and carports are not permitted in the front setback.
  • Side: 900mm to external walls.
  • Rear: 4m for single storey, 6m for two storey.

There is a useful exception at the rear. Clause B1(f) allows council to consider a non-habitable building, such as a shed, that does not meet the rear setback, if you can show it has minimal adverse impact on your property or the neighbours'. Rear setback areas are also meant to stay mostly landscaped, which affects where the shed sits even when the distance is met. The building envelope in B2 also applies, measured from natural ground level at the side boundary.

These DCP numbers apply to a DA. A complying development certificate is tested against the setbacks in the Codes SEPP, and your certifier will confirm which ones apply to your lot.

Do heritage and bushfire overlays stop you building a shed?

Usually not. Two carve-outs in the Codes SEPP catch people out.

Heritage: clause 1.19(1)(a) rules out complying development in a heritage conservation area, but it exempts detached outbuildings and detached development, other than a detached studio. A conservation area alone does not push a shed to a DA. A heritage item on your lot is a different matter and goes to the certifier.

Bushfire: clause 1.19A blocks complying development on land rated BAL-40 or Flame Zone. Under clause 1.19A(2), that does not apply to non-habitable detached development more than 6m from the dwelling house. Under 1.19A(4), the restriction applies only to the part of the lot that is BAL-40 or Flame Zone. A bushfire-prone mapping category is not a BAL rating. A consultant assesses the BAL on the specific site.

Flood is the overlay to take seriously, especially near the Nepean. Under clause 3.5, a flood control lot needs council or a hydraulic engineer to certify the building area is not a floodway, flood storage area or high hazard area before a certificate can issue. Flood is checked early on every job, so we look at it before we talk size.

Other things can rule out complying development too, such as certain acid sulfate soils, contaminated land and land under a biobanking agreement. Clause 1.19 lists them.

What if your shed is bigger than the complying limit?

You have two choices: reduce the shed to fit the band, or lodge a DA with Penrith City Council. A DA is assessed on merit under section 4.15 of the Environmental Planning and Assessment Act 1979. Section 4.15(3A)(b) says that where a DCP standard is not met, council must be flexible and allow reasonable alternative solutions that achieve the objects of the standard.

In Penrith that matters, because the DCP has no floor area cap. A larger shed can be argued on setbacks, bulk, overshadowing and neighbour impact. Nobody can promise how council will decide, and a DA takes longer than a certificate. When a shed misses the complying limit by a small margin, trimming it is often the simpler path. If you want the full size, a DA is the route.

What does Upspec check on sheds in Penrith?

Before we talk size, we check the zone, the actual lot area, any existing sheds or carports that count toward the cap, flood, bushfire and heritage mapping, and where the shed can sit against the boundaries. Our domestic sheds range and the design your shed tool are good places to test sizes. Our Penrith sheds page covers the local area.

Upspec is a licensed NSW builder (licence 359673C). We lodge the approval paperwork and pay the fees on your behalf, and we manage the whole job under one contract. You pay drafting, admin and application fees whether or not approval is granted. Any council contributions are paid directly to council by you. We never build before approval. Our minimum job is 4m x 6m.

Common questions

How big a shed can I build in Penrith without a development application?

Up to 20m2, a garden shed on a residential block can be exempt and needs no approval. Above that you need a complying development certificate from a certifier, and the limit depends on the lot: 36m2 for a lot of 200m2 to 300m2, 45m2 over 300m2 up to 600m2, 60m2 over 600m2 up to 900m2 and 100m2 over 900m2, combined with any other sheds, garages and carports. Rural zones have different rules. Your certifier confirms the final figure.

Does the limit depend on my actual lot area or the minimum lot size?

It depends on your actual lot area. The minimum lot size is a subdivision control and does not set your band.

How far does a shed have to sit from my boundaries?

For a complying development certificate, the shed setbacks are set by the Codes SEPP. We have not listed them here because they vary with the lot, and your certifier confirms them. The DCP figures that follow are for a DA. Under Penrith DCP Part D2, the side setback is 900mm and the rear setback is 4m for single storey, with a possible reduction for non-habitable structures if the impact is minimal.

Who decides whether my lot qualifies?

A registered certifier decides for a complying development certificate, and Penrith City Council decides a DA. This post is a guide, not a determination. The NSW Planning complying development page explains the process.

Next step

Send us your address and the size of shed you have in mind, and we will tell you which pathway it looks like it follows and what to check first. Contact us through our get in touch page or call 1300 487 773.

Back to Blog

1300 487 773

1/31 Coombes Drive, Penrith NSW 2750

© copyright 2026, Upspec Steel Buildings. Powered By Click To Build